Victron Energy 100A Autotransformer

£897.32 £761.26 Save 15%

An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention. This model is rated to 100A.

Sorry, this product is not available to purchase in your country.

SKU: ITR000100101 Category:

One percent of this purchase goes to planting trees and advancing access to solar energy 🌱
Find out more

Campervan electrics leaving you confused?

Our team of engineers will design your perfect system, bespoke to your needs 👌
Discover more It's free

    The Autotransformer: for step up, step down and split phase balancing

    An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.

    Consider for example a 30A 120/240V split phase supply.

     

    The supply could be the grid, a generator or two stacked inverters

    Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity.

    Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2 kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum.

     

    The solution is an Autotransformer

    By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A.

    Product SKU: ITR000100101


    Weight 13.5 kg
    Dimensions 42.5 × 21.4 × 11 cm
    Brand

    Victron Energy

    Manufacturer Part Number

    ITR000100101

    Input Circuit Breaker

    100A, two pole

    Maximum 240V Feed Through Current

    100A

    Transformer Type

    Toroidal

    Protection Category

    IP21

    Current (A)

    100

    Warranty

    5 Years

    Country of Manufacture

    India

    Product or kit

    Product